TRIPPLITE 1000VA/800W OnLine 2U rack UPS

Kód

26356373

Part No.

SUINT1000LCD2U

 
Výrobce
Tripp-Lite
Vaše cena bez DPH
20 998 Kč
Recyklační poplatek
25.00 Kč , DPH:  21%  (Záložní zdroje UPS od 15 do 50 kg všechny velikos)
Vaše cena  s RP*
21 023 Kč
DPH
21%
Vaše cena s DPH
25 438 Kč
Záruka
24 Měsíce
Dostupnost

Podrobnosti

Output Volt Amp Capacity (VA) 1000
Output kVA Capacity (kVA) 1
Output Watt Capacity (Watts) 900
Output kW Capacity (kW) 1
Output Capacity Details DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 630 watts for 208/220/230/240V output voltages; Max output is 720W (504W in Frequency Conversion mode) at 200V output voltage OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 3 minutes, 150% for 30 seconds and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits).
Power Factor 0.9
Crest Factor 3:1
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Nominal Voltage Details Nominal output voltage is user configured on first power-on
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 2%
Output Receptacles (6) C13
Included Output Power Cables Includes 2 C13 to C14 power cables
Load Management Receptacles Two switchable 2-outlet load banks
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave

INPUT
Rated input current (Maximum Load) 4.99A
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type C14 inlet
Input Phase Single-Phase

BATTERY
Full Load Runtime (min.) 4.7 min. (900w)
Half Load Runtime (min.) 12.3 min. (450w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
External Battery Pack Compatibility BP24V15RT2U (limit 1);  BP24V28-2U (limit 1);  BP24V36-2US (multi-pack compatible);  BP24V70-3U (multi-pack compatible)
DC System Voltage (VDC) 24
Battery Recharge Rate (Included Batteries) Less than 4.1 hours from 10% to 90% (typical, full load discharge)
Internal UPS Replacement Battery Cartridge RBC24S
Battery Access Front panel battery access door
Battery Replacement Description Hot-swappable, replaceable batteries
Expandable Runtime Yes

VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning
Overvoltage Correction 2% output voltage regulation during overvoltages to 288V
Undervoltage Correction 2% output voltage regulation during undervoltages to 160V (100% load), 130V (70% load), 100V (30% load)

USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Interactive front-panel LCD interface reports UPS operating mode, detailed UPS status and site-power information; LCD interface also enables a variety of advanced UPS setup and configuration options
Switches 5 front panel switches: On/Off, Up, Down and Escape
Alarm Cancel Operation Power-fail alarm can be silenced by following on-screen prompts
Audible Alarm Audible alarm indicates power failure, low battery, overload and fault
LED Indicators 4 front panel LEDs: AC input (green), AC output (green), Battery (yellow), Fault (red)

SURGE / NOISE SUPPRESSION
UPS Dataline Suppression Details Single line dialup / network dataline protection included
EMI / RFI AC Noise Suppression Yes
AC Suppression Joule Rating 627
AC Suppression Response Time Instantaneous

PHYSICAL
Included Mounting Accessory Description 4 post installation accessories included
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary Form Factor Rackmount
UPS Power Module Dimensions (hwd, cm) 7.62 x 43.18 x 40.64
Rack Height (U Spaces) 2
Minimum Required Rack Depth (cm) 48.26
UPS Power Module Weight (kg) 12.70
UPS Shipping Dimensions (hwd / cm) 25.40 x 50.80 x 60.96
Shipping Weight (kg) 20.0
Cooling Method Fan
UPS Housing Material Metal
Primary UPS Height (mm) 762
Primary UPS Width (mm) 4,318
Primary UPS Depth (mm) 4,064
Shipping Height (mm) 2,540
Shipping Width (mm) 5,080
Shipping Depth (mm) 6,096

Produkt manažer:

Karel Štambera,  +420 226 217 368,  +420 725 307 609,  stambera@compos.cz

Poslat info

Dotaz k tomuto produktu

Váš e-mail
Dotaz
 
Stránka je chráněna pomocí Google reCAPTCHA

Nalezli jste jinde na internetu nižší cenu?

Váš e-mail
Cena bez DPH
Cena s DPH
WWW
Komentář
Mám o tento produkt zájem
 
Stránka je chráněna pomocí Google reCAPTCHA

Zaslat informaci o produktu známému

Váš e-mail
Zaslat na e-mail
Komentář
 
Stránka je chráněna pomocí Google reCAPTCHA

Nalezli jste chybu?

Popis závady
Váš e-mail
 
Stránka je chráněna pomocí Google reCAPTCHA

Vaše firma jsme My!

Vyzkoušejte si náš osobní přístup, rychlost komunikace a dodávky, dostupnost i těžce dostupných produktů a odbornost, díky které jsme oficiální distributor serverů Supermicro.

Kontaktujte našeho specialistu