Output kVA capacity (kVA) 8
Output Watt Capacity (watts) 7200
Output kW capacity 7.2
Output power factor 0.9
Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Nominal Voltage details Voltage selection via front panel LCD interface
Frequency compatibility 50/60 Hz (auto-selectable)
Frequency compatibility details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (output de-rates by 25% in frequency conversion mode)
Output voltage regulation (line mode) +/- 2%
Output voltage regulation (Economy line mode) +/- 10%
Output voltage regulation (Battery mode) +/- 2%
Built-in UPS output receptacles 4 L6-20R outlet(s); 2 L6-30R outlet(s)
Output circuit breaker 20A double-pole (x2) protects 2 L6-20R outlets each, 30A double-pole (x2) protects 1 L6-30R outlet each
Basic PDU options PDU1230 (1U / 2 C19, 16 C13 outlets); PDUNV (1U / 2 C19, 12 C13 outlets); PDUV30HV (0U / 6 C19, 32 C13 outlets)
Metered PDU options PDUMV20HV (0U / 6 C19, 32 C13 outlets); PDUMV30HV (0U / 6 C19, 24 C13 outlets)
Monitored PDU options PDUMNV20HV (0U / 4 C19, 20 C13 outlets); PDUMNV30HV (0U / 4 C19, 20 C13 outlets)
Switched PDU options PDUMH20HVNET (1U / 8 C13 outlets); PDUMH30HVNET (2U / 16 C13 outlets); PDUMV20HVNET (0U / 4 C19, 24 C13 outlets); PDUMV30HVNET (0U / 4 C19, 24 C13 outlets)
Output AC waveform (AC mode) Sine wave
INPUT
Rated input current (at maximum load) 46A (200V), 44.2A (208V), 41.8A (220V), 40A (230V), 38.3A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS input connection type Hardwire
UPS input connection description 3 wire single phase input (L1, L2, G)
BATTERY
Full load runtime (minutes) 5.5 min. (7200w)
Half load runtime (minutes) 13.5 min. (3600w)
Expandable battery runtime Supports extended runtime with optional external battery packs
External battery pack compatibility BP240V10RT3U; BP240V557C-1PH; BP240V787C-1PH; BP240V1037C-1PH; BP240V1407C-1PH
DC system voltage (VDC) 240
Battery recharge rate (included batteries) Less than 6 hours from 10% to 90%
Battery replacement description Hot-swappable, user replaceable external battery packs
VOLTAGE REGULATION
Voltage regulation description 2% output voltage regulation in standard online, double-conversion mode
Overvoltage correction Corrects overvoltages up to 300V
Undervoltage correction Corrects undervoltages as low as 100V
LEDS ALARMS & SWITCHES
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Front panel LCD display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Alarms Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation Alarm cancel switch
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
SURGE / NOISE SUPPRESSION
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes
PHYSICAL
Installation form factors supported with included accessories Tower
Included mounting accessory description 2 sets of adjustable 4 post rack rails included; 2-9USTAND tower kit included (supports up to 9U in tower format)
Installation form factors supported with optional accessories 2 post rackmount (2POSTRMKITHD)
Optional mounting accessory notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack
Primary form factor Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 5.14 x 17.5 x 25.82
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) 13.1 x 44.4 x 65.6
Installed whole system maximum rack depth (inches) 32.5
Installed whole system maximum rack depth (cm) 82.6
Installed whole system total rack space height (rack spaces) 6U
Secondary form factor Tower
UPS / Power Module weight (lbs) 43
UPS / Power Module weight (kg) 19.5
Included battery pack dimensions (height x width x depth / inches) 5.25 x 17.5 x 25
Included battery pack dimensions (height x width x depth / cm) 13.3 x 44.4 x 63.5
Included battery pack weight (lbs) 158.7
Included battery pack weight (kg) 72
UPS Shipping dimensions (height x width x depth / inches) 39.8 x 31.5 x 23
UPS Shipping dimensions (height x width x depth / cm) 101 x 80 x 58.4
Shipping weight (lbs) 331
Shipping weight (kg) 150.3
UPS housing material Steel
Cooling method Fan
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 2732
AC economy mode BTU / hr. (full load) 1020
AC economy mode efficiency rating (100% load) 96%
Operating Elevation (ft) 0-3000m (0 to 10,000 ft.)
Audible Noise 60 dBA at front side 1 meter
COMMUNICATIONS
Communications interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring port description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
PowerAlert software Included
Communications cable USB, DB9 serial and EPO cables included
WatchDog compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications